New Building Regulations Introduced in Bihar

Patna, November 16: New building regulations have been implemented in Bihar for the construction of houses and buildings. Following the approval of the Building Construction Act, 2026 by the Samrat Chaudhary Cabinet, the Urban Development and Housing Department has issued a notification. Any new construction or modifications to existing buildings in urban areas of the state must now comply with these new by-laws. The government has simplified several processes to facilitate the construction of homes while also establishing specific standards.
Minimum Room Size and Height Requirements
Under the new regulations, minimum area, width, and height standards have been set for various parts of residential buildings. Clear specifications have been provided for rooms, kitchens, bathrooms, toilets, doorways, and parapets. The minimum area for a livable room must be 9 square meters (97 square feet) with a width of 2.4 meters. This means that rooms cannot be less than 8 feet wide. Additionally, the height of the room must not be less than 2.75 meters, which is approximately 9 feet.
Specifications for Kitchen, Store Room, and Bathrooms
The new regulations specify that the minimum area for kitchens must be 4.5 square meters with a width of 1.8 meters (approximately 5.9 feet). The minimum area for a store room is set at three square meters (approximately 32.3 square feet). Similarly, the area for bathrooms is required to be 1.8 square meters (19.38 square feet) and for toilets, it is set at 1.2 square meters (12.92 square feet).
For an attached toilet-bathroom, a minimum space of 2.8 square meters (30.14 square feet) is necessary. The width of doorways must be at least 0.9 meters (3 feet). The height of the platform should be between 0.45 to 0.9 meters, and the height of the parapet should be between 1.2 to 1.5 meters.
Streamlined Approval Process for Small Buildings
The new building regulations provide relief to those constructing small houses. For buildings with a height of 10 meters or less, there is no need to go through local bodies or authorities for approval. The requirement for map approval for such buildings has been eliminated. However, for buildings exceeding this height, approval is still mandatory. The new rules have simplified the process compared to the previous regulations, which required approval for all procedures.
Exemption from Fire NOC
Residential and commercial buildings are exempt from obtaining a Fire No Objection Certificate (NOC) under the new regulations. After receiving map approval, there is no need for an NOC. However, applicants must adhere to all necessary fire safety standards. Architects preparing the plans must ensure the provision of fire extinguishers, exits, alarms, sprinklers, hoses, and adequate water storage. Despite the exemption from the NOC, third-party fire consultants or departmental fire officers can inspect under the Bihar Fire Safety Act, 2014. Any discrepancies found must be rectified, or the building may be sealed.
Application Fees Required
Applicants must submit their applications online in the prescribed format. The Urban Development Department has launched a portal for this purpose. After submitting the application, the required fees must also be paid. The new regulations state that all types of fees will be charged according to the rates and procedures implemented by the local bodies or authorities from time to time.
| Type | Previous Rules | New Rules |
|---|---|---|
| Map Approval | Mandatory | Exemption for low-height buildings |
| Access Road | Minimum 20 feet | Minimum 12 feet |
| Setback | Minimum 4 feet | Exemption (as per convenience) |
| FAR (Floor Area Ratio) | 2 | 3 |
| Fire NOC | Mandatory | Included with map approval |